  Unique Descalers
  delta
 

888 DESCALE - Industrial Descaler

DeltaSafe D Scale - Universal Descaler

Safe D Scale PLUS - Extra Strength Descaler

DeltaDISSOLVE - Institutional Descaler

DeltaKLEAN - Building Systems Descaler

ScaleOUT Cleaner - Closed-Loop Descaler

MarineGEL - Vertical Surface Descaler

GlyKLEAN - Closed-Loop Glycol Descaler

Radiator PLUS - Glycol Deposit Descaler

Radiator PLUS Concentrate - Concentrated Descaler

 

Specifically designed to safely dissolve all water scale, lime, rust and other water-formed deposits. Biodegradable & SAFE to dispose down plant sewers without harm to people or any equipment.

APPLICATIONS:

Delta Descalers are scientific liquid descalers specifically designed to dissolve all water scale, lime, rust and other water formed deposits which are found in any type of water operated heat transfer or cooling equipment and systems.

Each gallon of Delta Descaler will effectively dissolve approximately two pounds of deposit, restoring operating efficiencies to equipment and heat transfer surfaces. Other benefits include lower head pressures, reduced power consumption, cooler and more efficient operations, increased water flow, and extended equipment life.

Delta Descalers are biodegradable, non-toxic, non-corrosive, and non-flammable when used as directed. The material may be disposed of down regular sewer drains with a water flush per local regulations. Delta Descalers are safe enough to hold in the open hand. There are no hazards to your equipment, personnel or environment.

Most Delta Descaler cleanings may be accomplished within an average of two to four hours of circulation time. Some systems may be cleaned while in operation without the need for shutdown. There is no need to neutralize after cleaning; simply flush dissolved deposits with water and return unit to service.

Suggested Delta Descalers cleaning concentrations:

Boilers: One gallon or less per boiler horsepower.  Heating surface times thickness

Condensers and Towers: One gallon per every two to three tons of cooling capacity

Heat Exchangers: 50-50 water to Delta Descaler dilution per total unit volume

COOLING TOWER SYSTEMS:

Check spray orifices and clean pans to assure maximum coverage. Thoroughly flush entire system to remove all loose deposits and refill with the minimum amount of clean water to maintain pump circulation. Turn off make-up and bleed-off valves. Slowly add approximately one gallon Delta Descalers for every two tons of tower cooling capacity and circulate until all foaming action stops. Drain and flush system directly to sewer and refill tower, or bleed-off and overflow dissolved solids over several days.

BOILERS, CONDENSERS AND HEAT EXCHANGERS:

Thoroughly flush entire system to remove all loose deposits. Connect circulation pump to lower inlet piping and return to circulation bucket from top of unit. Circulate the suggested Delta Descalers concentration for two to four hours depending on foaming action of discharge. When foaming stops determine Delta Descalers strength by activity on clean concrete. If the solution still foams, equipment should be clean. If there is no foaming action evident, the used material has dissolved its capacity and more fresh Delta Descalers may be added for additional circulation until completely clean. Drain and flush entire system directly to sewer with clean water and refill.

 